Russell's Feedback:
Instead of two buildings to compare building construction types which we previously decided to go ahead with we will now change:
- The remodel of the Sample Project to Australian building standard types (exp. Precast concrete changed to reinforced block retaining walls and brick veneer.
- To create another model constructed out of Double brick with piers with cut and fill.
We will now keep the Sample Project entirely constructed as is only checked to Australian Standards and the Building Code.
We will now create another building constructed out of timber frame construction to show the client the cheaper alternative? more sustainable? lighter structure? more time efficient? - These options can be discussed with the builder/ client once the BIM to CryEngine resource is provided.
Objective
To make our project as if it was a 'real life' project, to be planned, designed and constructed in the Eastern Suburbs of Sydney. We have now assumed data for our site to collect information, standards and legislation to follow when we are designing our buildings for construction.
Assume:
Location- Dover Road, Dover Heights
Site Classification- Class A, Sand and Rock
Council- Waverley Council
Legislation- Development Control Plan and Development Control Plan
Quick view through the legislation:
Mapping - R2 Low Density Residential
Building Height Max - 8.5m
Heritage - Not Applicable
Floor Space Ration - 50:1
Side setbacks - 900mm
Rear building line - rear line of neighbouring buildings
Fences - 1200mm high (max)
Aim
To design and plan following the state and local legislation
Objective
To make our project as if it was a 'real life' project, to be planned, designed and constructed in the Eastern Suburbs of Sydney. We have now assumed data for our site to collect information, standards and legislation to follow when we are designing our buildings for construction.
Assume:
Location- Dover Road, Dover Heights
Site Classification- Class A, Sand and Rock
Council- Waverley Council
Legislation- Development Control Plan and Development Control Plan
Quick view through the legislation:
Mapping - R2 Low Density Residential
Building Height Max - 8.5m
Heritage - Not Applicable
Floor Space Ration - 50:1
Side setbacks - 900mm
Rear building line - rear line of neighbouring buildings
Fences - 1200mm high (max)
Aim
To design and plan following the state and local legislation
Image01: Our chosen site in Dover Heights
maps.google.com.au
New Work:
Model 01:
-Original Model
-Check NCC and Aus Standards
Previous research work that can be included:
-Pad footings for steel structure (1000x1000x500mm) min 500 below ground level
-New Drywall on basement walls ( Timber stud)
- Check specifications for timber sizes (Hyspan on Dropbox, Acceptable standards of domestic construction)
- Concrete reinforcing ( Acceptable standards of Domestic Construction lists the trench mesh sizes as well as the reinforcement bars, lapping, there needs to be cover for the concrete (min. 50mm)
- Spans for construction ( Acceptable standards of Domestic Construction)
Need to model:
-Reinforcing Supports (Chairs)
-Formwork + bracing
Model 02:
-New model
-Timber frame construction (Floor, walls etc.)
Include:
-Brick piers
-Ant-caps
-Cladding - Blueboard or Weatherboard
Research
-Spans
-Load-Bearing
-Timber specifcation sizes for Australia